AC5000 PRODUCT DATA


Tough Stuff AC5000 is designed to provide long lasting, trouble free systems for the renewal and maintenance of all types of surfaces.

smallpdf.gifVIEW / DOWNLOAD (Windows - "Right Click", Mac - "Option-Click") a printable PDF version of this document.

RECOMMENDED USES

PRODUCT CHARACTERISTICS

APPLICATION CONDITIONS
APPLICATION PROCEDURES
PERFORMANCE TIPS
CLEANUP INSTRUCTIONS
SAFETY PRECAUTIONS

ORDERING INFORMATION

RELATED DOCUMENTS


RECOMMENDED USESup.gif

  • Metal, tile, concrete, masonry, slate, built up, shingles, urethane foam, modified bitumen, existing single ply, and most other building materials.


PRODUCT CHARACTERISTICSup.gif

FINISH: Eggshell
COLOR: Contact Coatings International for availability, lead times, and pricing for special colors
VISCOSITY: 2,000-3,000 cps
WEIGHT PER GALLON: 12.1 pounds / gallon
VOC (EPA method 24): 16.5 grams / liter
SHELF LIFE: 6 months unopened
CLEANUP: Do not thin. Use clean water for cleanup.
FLAMMABILITY: Nonflammable
RECOMMENDED SPREADING RATE PER COAT: 75 square feet / gallon


Drying Schedule: At 75 square feet / gallon:

dot.gif 50°F 70°F 110°F
To Touch 90 min. 30 min. 10 min.
To Recoat 1 day 6 hours 4 hours
To Cure 30 days 15 days 10 days
Drying time is temperature, humidity, and film thickness dependent.

PHYSICAL
PROPERTY
ASTM
TEST
METHOD
TYPICAL
VALUE
Solids by Weight D 1353 66% ± 2
Solids by Volume D 2697 50% ± 2
Tensile Strength D 412 250 psi ± 20
Hardness D 2240 50 Shore A

PROPERTY TEST PROCEDURE RESULT
Accelerated Weathering UV Resistance Atlas Carbon Arc Weather Ometer Type EH-Continuous UV and water spray cycling at elevated temperature. ASTM D822, ASTM G23 After 2,000 hours of continuous exposure, Tough Stuff AC5000 showed no deterioration, no surface checking, cracking, or delamination.
Resistance to Wind Driven Rains
Pressurized test chamber producing 5 " (12.5 cm) of water pressure, equivalent to 100 m.p.h. wind pressure (161 km./hr.). Federal Spec TTC-555B During 40 hours of continuous testing, no apparent moisture penetrated the Tough Stuff AC5000 sample.
Resistance to Salt Spray Harshaw Salt Spray Cabinet (5% NaCl fog solution). ASTM B117 After 500 hours of continuous exposure, Tough Stuff AC5000 showed no deterioration, no surface chalking, cracking, or delamination.
Resistance to Mildew Five different fungus cultures grown on potato dextrose agar in an 86ºF (30ºC) incubator. ASTM G21 After 14 days, all Tough Stuff AC5000 samples showed absolutely no fungus growth.
Film Breathing Ability
Honeywell Water Vapor Transmission Rate Tester. ASTM E398 At 15 mils dry (381 microns) Tough Stuff AC5000 has a perm rating of 4.5 allowing moisture vapor within building to pass through the coating while preventing the penetration of mass water from the exterior.
Elongation after Aging Atlas Carbon Arc Weather-Ometer Type EH, ASTM D822, ASTM G23, and Instron Universal Testing Instrument, ASTM D412. After 2,000 hours exposure in the Weather-Ometer, Tough Stuff AC5000 retained 95% of its elastomeric properties.
Low/High Temperatures Aged films tested in accordance with ASTM D822 in thermostatically controlled heat chamber and freezer. Films retained their ability to be flexed 180º without cracking at temperatures from -30ºF to 200ºF (34-94ºC) with no age hardening or slump.

APPLICATION CONDITIONSup.gif

TEMPERATURE

Air and Surface: 50ºF Minimum, 100ºF Maximum
Material: 50ºF Minimum, 100ºF Maximum

RELATIVE HUMIDITY

Can be applied at relative humidities up to 90%


APPLICATION PROCEDURESup.gif

GENERAL

BRUSH:

No reduction necessary. Use nylon/polyester brush. Do not over brush as material may start to pull.

ROLLER:

No reduction necessary. Use 1/2" to 1 1/2" nap synthetic rollers. Keep a wet edge to avoid ripping which may change appearance. If ripping is a problem, extend lap time to after materials have skinned. Avoid rapid rolling which causes bubbling.

AIRLESS SPRAY - HIGH VOLUME:

Pressure: 3,000-4,000 psi
Tip: .37-.56 reversible
Reduction: None necessary


PERFORMANCE TIPSup.gif

  • DO NOT THIN
  • POWER MIX BEFORE USING

HIGH TRAFFIC AREAS

  • Walkways must be installed on insulated systems anytime considerable roof traffic is expected.
  • An extra layer of polyester and Tough Stuff AC5000 with #11 roofing granule can also be added to traffic areas instead of walk pads.


MILDEW

  • Must be removed by power washing and broom scrubbing with a solution of 16 oz. household bleach with 2 oz. Tough Stuff 404 or liquid detergent / gallon of water. Rinse clean and dry thoroughly


CURING PRECAUTIONS

  • If moisture settles on uncured Tough Stuff AC5000 for a period of time, a brown residue may form on the surface. While this residue will not affect the performance of the cured film, it must be removed prior to applying an additional coat of Tough Stuff AC5000.

  • A good way to avoid this residue is to broom off any water in the morning with a soft bristle broom while drying the roof. If residue has been allowed to dry, add clean water and broom scrub the surface, rinse off residue, and allow to dry.

  • Stubborn areas may require hot water and trisodium phosphate solution.

  • Common sense and strict adherence to application procedures will prevent this problem.

  • Brown spots can also be scrub primed with Tough Stuff AC5600, allowed to dry, and recoated with Tough Stuff AC5000.

Please consult Coatings International for specific questions regarding the application of this product.

CLEANUP INSTRUCTIONSup.gif

Clean spills and spatters immediately with water

Clean hands and tools immediately after use with soapy water.

After cleaning, flush spray equipment with water followed by mineral spirits to prevent unit from rusting.


SAFETY PRECAUTIONSup.gif

INSTALLERS must read and understand all technical and informational literature for Tough Stuff AC5000, including the Material Safety Data Sheets, prior to using this product.

For chemical emergencies, spills, leaks, exposure, or accidents in the U.S.: CALL CHEMTREC 24 HOURS A DAY / 365 DAYS A YEAR 1-800-424-9300.

ORDERING INFORMATIONup.gif

Packaging:

Container Size Weight Class
5 gallon cans 62 lbs. 55
55 gallon drum 685 lbs. 55

DOT Shipping Information:

Acrylic Roof Coating
Nonhazardous

HMIS:

Health 1, Flammability 0, Reactivity 0, Protection B

Published technical data and instructions are subject to change without notice. Please contact your Coatings International Roofing Systems representative for the most current information.

Revised November 2003

FOR ADDITIONAL INFORMATION, GO TO:up.gif

See also:

Coatings International Products Page
Coatings International Home Page
Coatings International Information Request Form


E-mail info@coatingsinternational.com
©Copyright 1998-2004 Coatings International, Inc. All rights reserved.
This page was last modified January 20, 2004 01:49PM.